View
of meter (cut away) with wire in U-shaped channel.

View of spark plug wire with pickup wire wrapped around
4 times.

Operating
Instructions
Push and release mode control to toggle
between Hour Meter, Tachometer, Job Timer, and Service
Alarm (SVC TIME, SVC SET).
Hour Meter
- Indicated by "TOT TIME" on display (non-resettable
accumulated running hours.)
Tachometer - Upon entering this function,
you will see "P1", "P2", or "P3"
for 3 seconds on the right-hand side of the display.
This is the current programmed firing pattern. To access
MAXTACH (highest engine RPM), be in the RPM mode and
hold the mode button down for at least three seconds.
To erase the high RPM, continue holding down for at
least 9 seconds (will see 0000). To change the firing
pattern, be in the RPM mode and hold the mode button
down for more than 10 seconds, then release the button
on the desired firing pattern ("P1", "P2",
or"P3").
Job Timer
- To view the JOB TIME, push and release the mode button
until the display reads "JOB TIME". To reset
to zero, depress the mode button for three seconds (time
will clear to 0.0)
Service Time
- This is the time built up since your last maintenance.
To view the Service Time, push and release the mode
button until the display reads "SVC TIME".
When this time exceeds what you set in SVC SET, the
display will start flashing (alarming you to perform
maintenance). After the maintenance is performed, hold
down the mode button for 3 seconds. This will clear
the SVC TIME to 0.0 and the alarm will stop flashing.
You are now ready to go toward your next maintenance
interval.
Service Set
- This is where you set the desired maintenance interval.
To view the set maintenance interval, push and release
the mode button until the display reads "SVC SET".
To set a different service interval, push and hold the
mode button until the desired interval appears on the
display. Then simply release the mode button and that
is your new service interval. (The mode button must
be held down for at least 3 seconds before the Service
Set intervals begin to increment.
-