INSTALLATION DIAGRAMS
& INSTRUCTIONS
All dimensions in inches. To print figures individually,
right-click on the image and save to your local computer.
Step 1
Find a convenient mounting location, be sure the pick-up
wire will reach the spark plug wire. If not, substitute
with a wire of the same outside diameter of no less
than 22 gauge, up to 8 feet long. DO NOT mount meter
where surface temperature exceeds 125 F. As a general
guideline, if you can place your hand on the mounting
surface without discomfort while equipment is at full
operating temperature, then it will be suitable to mount
meter in that location.
Step 2
Use drill template (Fig. 1) to locate mounting holes.
DO NOT DRILL INTO GAS TANKS OR ENGINE CRANKCASE; if
in doubt, contact your dealer.

Step 3
Secure pick-up wire into meter by placing wire over
channel and pushing down with a flat screwdriver. Wire
must be seated completely in channel (see Fig. 2). Fasten
meter to mounting surface with supplied screws. Route
wire to spark plug wire and attach as shown in Figure
3.

|